DM Engineers

Storm Drainage Roof drains, leaders & storm drains

Plumbing · Storm drainage · PCNYS 2025

Design aid based on the 2025 Plumbing Code of New York State, Chapter 11. Results must be reviewed and verified by a licensed professional engineer before use in construction documents. In New York City, the NYC Plumbing Code governs; verify its requirements before using these results there. This tool does not cover siphonic or controlled-flow roof drainage, or structural rain loads.

Project

Shown in the report and saved with the project.


Design basis

in/h

Use PCNYS Figure 1106.1 or approved local weather data (1106.1). Verify the value for the project site with NOAA Atlas 14.

%

Optional margin added to the code flow. The code itself uses R × A × 0.0104 (Eq. 11-1); enter 0 to use it alone.

Horizontal storm drain slope

Inches per foot. A zone can override it.


Project file

Save the project with its results to an .xlsx file, edit or add zones in Excel if needed, and open it again here.

Tool version 0.7.1

Roof zones

One zone per roof area that drains to its own group of drains. A zone can have drains of different sizes, each with the roof area it collects.

How to use

1. Design basis

  • Rainfall rate R: the 100-year, 1-hour rate for the project site, in inches per hour, from PCNYS Figure 1106.1 or approved local data such as NOAA Atlas 14.
  • Safety factor: optional margin over the code flow. Enter 0 to use the code value alone.
  • Horizontal slope: slope of the horizontal storm drains, in inches per foot. Each zone can use its own.

2. Roof zones

  • Make one zone for each roof area that drains to its own group of roof drains. Give every zone a different ID.
  • Projected roof area: the area seen from above. Vertical wall area: walls that shed rain onto that roof; half of it is added.
  • Roof drains: how many drains, their size (optional, for the report), the flow each one handles from the manufacturer's catalog at the design water depth, and the roof area they collect. The area of a line is split equally among its drains.
  • Drains of different sizes in one zone: press Add drains of another size and give each size the roof area it collects, from the roof plan. Example: a 7,925 ft² roof with two 6 in drains and one 3 in drain at a lower center strip of 1,118 ft² has two lines, 2 drains with 6,807 ft² and 1 drain with 1,118 ft². Each drain is checked with its own flow, and the horizontal pipe is sized for the whole zone.
  • All drains connect to one leader: tick it when the zone's drains join one vertical pipe. That pipe is sized for the zone's total flow, by Table 1106.2 (vertical drain) and Table 1106.3 (leader). The sizes on each drain line are then the connection from each drain.
  • Each zone shows its flow and pipe sizes as you type. Zones with a problem are outlined in orange and explained above the results.

3. Secondary (emergency) system

  • A roof with a parapet or raised edge holds water like a tray. If the roof drains are blocked, the water must still get out, so the code requires a second system that works only in that case (PCNYS 1108). It is sized for the zone's whole flow, as if the roof drains were fully blocked, and does not change the primary results.
  • Overflow drains: drains set higher than the roof drains, with their own piping that discharges where it can be seen. Enter how many the zone has. The report gives the flow for each one and its vertical and horizontal pipe sizes.
  • Scuppers: openings through the parapet. Enter how many, their width, the water depth over the bottom of the opening, and the opening height. The report checks their capacity, the minimum width and the minimum 4 in height (PCNYS 1106.5).
  • Not required: only where no parapet or raised edge can trap water on the roof. The report notes it for the engineer to confirm.

4. Results and report

  • The primary system table uses the same columns as the PE's spreadsheet. It gives both vertical sizes for each drain: Vertical Drain Size (interior conductor, Table 1106.2, vertical drain column) and Vertical Leader Size (Table 1106.3). Use the one that matches the piping.
  • The report below the zones lists every result with the code section it comes from. Print / save PDF prints it or saves it as a PDF.
  • Inputs are kept in this browser until you press Clear. They are not sent anywhere.

5. Saving and editing the project in Excel

  • Save as Excel downloads the project as an .xlsx file with its inputs and results. Keep it with the project files.
  • To change the project later, press Open Excel… and choose the last file you saved. The tool loads it and recalculates everything.
  • You can also edit the file in Excel before opening it:
    • Change values only in the Project sheet (column B) and the Zones sheet.
    • In Zones, add a zone by filling a new row below the last one. Delete a zone by deleting its row. Do not change the column titles.
    • Zone IDs must be different. Areas in ft², capacities in gpm, scupper sizes in inches.
    • Slope: 1/16, 1/8, 1/4 or 1/2, or leave it blank to use the project slope.
    • Secondary system: Overflow drains, Scuppers or Not required.
    • The Results sheet is only a copy for reference. It is ignored when the file is opened, because the tool recalculates.
  • If something in the file is wrong, the tool does not load it and tells you the sheet and row to fix.